Dolphin Pediatric Fluid Immersion Simulation V-Matt System including 35" x 88" x 10" Mattress and Dolphin Pediatric AutoVector Control Unit designed as replacement system for Step Deck beds

Sale
$33,627.00$29,592.00

Short Description

The Dolphin Fluid Immersion Simulation (FIS) System is an advanced therapy system designed to provide state-of-the-art pressure redistribution by simulating the effects of a body immersed in a fluid medium. The Dolphin System automatically measures the specific characteristics of the individual patient as they engage the support surface creating an individualized immersion profile that creates a near neutral buoyant state. The Dolphin FIS System delivers three-dimensional volumetric engagement and eliminates gradient shear forces, leading to positive outcomes for flaps, grafts, and pressure ulcers. The Dolphin technology provides minimal tissue deformation, while maintaining near normal blood flow leading to improved tissue perfusion and wound healing.

Key Details:

 

  • Water Immersion Pain Management: Offer progressive therapy to patients through a revolutionary system that replicates the physical benefits of water immersion. This innovative approach has demonstrated remarkable success in pain management and optimal pressure redistribution, leading to improved blood flow and reduced soft tissue degradation.
  • Wound Treatment: Progressive submersion simulation system effectively treats and prevents wounds
  • Automated: Automatically conforms to each patient's body weight, shape, and repositions.
  • Manual Input Not Required: Does not require manual input
  • Long Battery Life: 12-hour backup battery life guarantees continuous treatment, even in the case of power disconnection or failure
  • Advanced Pressure Redistribution: Provides unmatched pain management with its innovative pressure redistribution

 

More Features:

 

The Dolphin FIS Pediatric Mattress offers advanced therapy for patients without them needing to leave their beds. By simulating being submerged in a fluid, it provides unmatched pressure redistribution and pain management, helping to treat and prevent wounds by reducing tissue degradation and promoting better blood flow. Patients with AIDS, arthritis, and undergoing oncology treatment have experienced significant relief with this system.

The therapy control unit operates the mattress automatically, adjusting to each patient's weight, shape, and movements. Monitoring the support surface over 100 times per second, it creates an individualized immersion profile for optimal comfort.

The Dolphin System addresses critical aspects of compromised skin treatment, including pressure redistribution, friction reduction, and shearing forces reduction. It effectively treats conditions like amputations, burns, grafts, flaps, and pressure ulcers, providing excellent pain management for those with AIDS, arthritis, and undergoing oncology treatment.

For added safety, the system alerts with an alarm and LED lights in case of disconnection or power loss. It comes with a rechargeable battery backup, ensuring continuous operation for up to 12 hours during power disruptions or failures.

Specifications:

 

  • Dimensions: 88"L x 35"W x 10"D
  • Therapy Mattress Weight: 22 lbs.
  • Therapy Mattress Weight Capacity: 300 lbs.
  • Pediatric Crib Mattress Weight Capacity: 300 lbs.
  • Operating Conditions Ambient Temperature: 50 - 104 Degrees (Fahrenheit), 10 - 40 Degrees (Celsius)
  • Operating Conditions Relative Humidity: 30% - 75% (Non-Condensing)
  • Storage and Shipping Conditions Ambient Temperature: 50 - 104 Degrees (Fahrenheit), 10 - 40 Degrees (Celsius)
  • Storage and Shipping Conditions Relative Humidity: 10% - 100%

 

Indications for use:

  • Patients who otherwise would be suitable for air fluidized therapy and would be most frequently used in the care of patients within intensive care, burns and plastics, vascular surgery and trauma & orthopaedic units.
  • Patients with pressure-related tissue damage and those undergoing flap surgery for pressure ulcer repair.
  • Prevention of skin breakdown in the most vulnerable of patients including spinal cord injury where the spine has been stabilised.
  • Pain management, including end-of-life care.
  • Where repositioning is challenging, for example for patients in ICU/CCU.
  • Patients who are non-concordant with repositioning.

DolphinCare-Brochure: Download

DolphinCare-Specification: Download

BedPanel-Specification-Sheet: Download

DolphinCare-for-SCI-Patients: Download

DolphinCare-System-Manual: Download

JHC-Dolphin-Manual: Download

Cura360 Return Policy

Most products featured on Cura360.com can be returned within 30 days of purchase depending upon the manufacturer’s return policy. 

For specific return information or authorization, please contact Cura360's Customer Service Department at [email protected] or call 833-207-3433 for authorization. Returns cannot be processed without contacting Cura360 first, and some items are non-returnable when opened due to health risks.


Generally, you can expect a credit or refund, less a restocking and handling fee, in the same form of payment originally used for your purchase. Credits will be issued within 30 days of the manufacturer receiving your returned product back complete and in good, unused condition in original packaging, and them issuing Cura360 an approval. You will be refunded the purchase price, less the Restocking Fee & applicable shipping fees. You are responsible for the return label and shipping costs. 

·       Restocking Fees range based on the Manufacturers policies, typically between 20-30%

·       All returns MUST be pre-approved by Cura360

·       If a return is not received by the carrier within 15 days after the request has been approved, we will consider the item as not returned and a refund will not be processed

·       Shipping costs are not reimbursable

·       Returns due to damage or defect must be reported as soon as possible and pictures may be required

IMPORTANT If there is significant visible damage to the packaging upon receipt, request that the driver note the damage and request a claim be filed with the carrier for damage. You should also immediately contact Cura360 Customer Service at  customerservice@cura360.com or call 833-207-3433

Joerns Healthcare warrants the Dolphin FIS System advanced support surfaces to be sold free from defects in workmanship and materials, under normal and proper use, for a period of two (2) years on the advanced support surfaces, and two (2) years on the electromechanical mattress components(compressors, valves, printed circuit boards, hoses, and couplers). Damages arising from improper use will not be covered by this warranty. 

Improper use is defined as, but not limited to, those caused by:

  • Burns
  • Use of improper chemical agents
  • Needle punctures, cuts, or abrasions
  • Excessive loads
  • Staining
  • Negligent or excessive usage
  • Improper maintenance, handling, and/or cleaning
  • Failure to use in the manner indicated in the Dolphin FIS System user manual

Any modification, repair, or alteration done to the Dolphin FIS System that was not authorized in writing by Joerns Healthcare will void this warranty. Damage caused by use in unsuitable environmental conditions, abuse, or failure to maintain the products in accordance with user and service instructions is not covered.This warranty is extended to the original purchaser of the equipment

Parts

Joerns’ Dolphin FIS System contains various parts that are worn for normal use. Joerns Healthcare’sobligation under this warranty is limited to supplying replacement parts, servicing, or replacing, at its option, any product which is found by Joerns to be defective. When requested by Joerns, parts must be returned for inspection at the customer’s expense. Credit will be issued only after inspection.

Service

Most service requests can be handled by the facilityMaintenance Department with assistance from theJoerns Healthcare Product Service Department. 

Most parts requested can be shipped next day air at the customer’s expense. 

Should a technician be required, one will be provided by Joerns Healthcare, at our discretion. Only theJoerns Healthcare Product Service Department can authorized technicians. 



The Delivery Option field is required
  • local_shipping Free shipping, arrives by Monday, December 09
  • local_post_office Shipping options: 3-5 Days

Safe Checkout:

  • PayPal
  • PayTomorrow
  • Discover
  • American Express
  • Master Card
  • Visa
  • Visa

Key Details:

 

  • Water Immersion Pain Management: Offer progressive therapy to patients through a revolutionary system that replicates the physical benefits of water immersion. This innovative approach has demonstrated remarkable success in pain management and optimal pressure redistribution, leading to improved blood flow and reduced soft tissue degradation.
  • Wound Treatment: Progressive submersion simulation system effectively treats and prevents wounds
  • Automated: Automatically conforms to each patient's body weight, shape, and repositions.
  • Manual Input Not Required: Does not require manual input
  • Long Battery Life: 12-hour backup battery life guarantees continuous treatment, even in the case of power disconnection or failure
  • Advanced Pressure Redistribution: Provides unmatched pain management with its innovative pressure redistribution

 

More Features:

 

The Dolphin FIS Pediatric Mattress offers advanced therapy for patients without them needing to leave their beds. By simulating being submerged in a fluid, it provides unmatched pressure redistribution and pain management, helping to treat and prevent wounds by reducing tissue degradation and promoting better blood flow. Patients with AIDS, arthritis, and undergoing oncology treatment have experienced significant relief with this system.

The therapy control unit operates the mattress automatically, adjusting to each patient's weight, shape, and movements. Monitoring the support surface over 100 times per second, it creates an individualized immersion profile for optimal comfort.

The Dolphin System addresses critical aspects of compromised skin treatment, including pressure redistribution, friction reduction, and shearing forces reduction. It effectively treats conditions like amputations, burns, grafts, flaps, and pressure ulcers, providing excellent pain management for those with AIDS, arthritis, and undergoing oncology treatment.

For added safety, the system alerts with an alarm and LED lights in case of disconnection or power loss. It comes with a rechargeable battery backup, ensuring continuous operation for up to 12 hours during power disruptions or failures.

Specifications:

 

  • Dimensions: 88"L x 35"W x 10"D
  • Therapy Mattress Weight: 22 lbs.
  • Therapy Mattress Weight Capacity: 300 lbs.
  • Pediatric Crib Mattress Weight Capacity: 300 lbs.
  • Operating Conditions Ambient Temperature: 50 - 104 Degrees (Fahrenheit), 10 - 40 Degrees (Celsius)
  • Operating Conditions Relative Humidity: 30% - 75% (Non-Condensing)
  • Storage and Shipping Conditions Ambient Temperature: 50 - 104 Degrees (Fahrenheit), 10 - 40 Degrees (Celsius)
  • Storage and Shipping Conditions Relative Humidity: 10% - 100%

 

Indications for use:

  • Patients who otherwise would be suitable for air fluidized therapy and would be most frequently used in the care of patients within intensive care, burns and plastics, vascular surgery and trauma & orthopaedic units.
  • Patients with pressure-related tissue damage and those undergoing flap surgery for pressure ulcer repair.
  • Prevention of skin breakdown in the most vulnerable of patients including spinal cord injury where the spine has been stabilised.
  • Pain management, including end-of-life care.
  • Where repositioning is challenging, for example for patients in ICU/CCU.
  • Patients who are non-concordant with repositioning.

DolphinCare-Brochure: Download

DolphinCare-Specification: Download

BedPanel-Specification-Sheet: Download

DolphinCare-for-SCI-Patients: Download

DolphinCare-System-Manual: Download

JHC-Dolphin-Manual: Download

Cura360 Return Policy

Most products featured on Cura360.com can be returned within 30 days of purchase depending upon the manufacturer’s return policy. 

For specific return information or authorization, please contact Cura360's Customer Service Department at [email protected] or call 833-207-3433 for authorization. Returns cannot be processed without contacting Cura360 first, and some items are non-returnable when opened due to health risks.


Generally, you can expect a credit or refund, less a restocking and handling fee, in the same form of payment originally used for your purchase. Credits will be issued within 30 days of the manufacturer receiving your returned product back complete and in good, unused condition in original packaging, and them issuing Cura360 an approval. You will be refunded the purchase price, less the Restocking Fee & applicable shipping fees. You are responsible for the return label and shipping costs. 

·       Restocking Fees range based on the Manufacturers policies, typically between 20-30%

·       All returns MUST be pre-approved by Cura360

·       If a return is not received by the carrier within 15 days after the request has been approved, we will consider the item as not returned and a refund will not be processed

·       Shipping costs are not reimbursable

·       Returns due to damage or defect must be reported as soon as possible and pictures may be required

IMPORTANT If there is significant visible damage to the packaging upon receipt, request that the driver note the damage and request a claim be filed with the carrier for damage. You should also immediately contact Cura360 Customer Service at  customerservice@cura360.com or call 833-207-3433

Joerns Healthcare warrants the Dolphin FIS System advanced support surfaces to be sold free from defects in workmanship and materials, under normal and proper use, for a period of two (2) years on the advanced support surfaces, and two (2) years on the electromechanical mattress components(compressors, valves, printed circuit boards, hoses, and couplers). Damages arising from improper use will not be covered by this warranty. 

Improper use is defined as, but not limited to, those caused by:

  • Burns
  • Use of improper chemical agents
  • Needle punctures, cuts, or abrasions
  • Excessive loads
  • Staining
  • Negligent or excessive usage
  • Improper maintenance, handling, and/or cleaning
  • Failure to use in the manner indicated in the Dolphin FIS System user manual

Any modification, repair, or alteration done to the Dolphin FIS System that was not authorized in writing by Joerns Healthcare will void this warranty. Damage caused by use in unsuitable environmental conditions, abuse, or failure to maintain the products in accordance with user and service instructions is not covered.This warranty is extended to the original purchaser of the equipment

Parts

Joerns’ Dolphin FIS System contains various parts that are worn for normal use. Joerns Healthcare’sobligation under this warranty is limited to supplying replacement parts, servicing, or replacing, at its option, any product which is found by Joerns to be defective. When requested by Joerns, parts must be returned for inspection at the customer’s expense. Credit will be issued only after inspection.

Service

Most service requests can be handled by the facilityMaintenance Department with assistance from theJoerns Healthcare Product Service Department. 

Most parts requested can be shipped next day air at the customer’s expense. 