Shop by Category
comment Live Chat

Ki Mobility Axiom SPF Fluid Wheelchair Cushion

Sale
$492.00$357.00

Short Description

Axiom SP Fluid takes advantage of the Axiom Difference and is designed to provide increased immersion and envelopment, using a Hydrolite fluid bladder instead of the Viscoelastic Foam used in the Axiom SP Visco.

Hydrolite Fluid Bladder

The Axiom SP Fluid uses a Hydrolite fluid bladder instead of Viscoelastic Foam. The bladder rests directly under the super stretch outer cover, allowing it to conform to the tissues supporting the Ischial Tuberosities.

Hydrolite is a non-Newtonian fluid that behaves as a solid under the force of gravity, but flows as a viscous fluid under load, which can help minimize shear. It is also incredibly light, eliminating the "weight penalty" of other fluid cushions. It is less temperature sensitive than other fluids, meaning it will provide more consistent performance regardless of climate.

Increased Immersion

Axiom SP Visco is designed to provide increased immersion, allowing the trochanters to bear an effective load. This improves stability by widening the base of support and reduces the load the tissue that supports the Ischial Tuberosities must bear. A thick section of specially designed Viscoelastic foam deforms to immerse and envelop the Ischial Tuberosities.

Increased Envelopment

Axiom SP Fluid is designed to provide increased envelopment, allowing the trochanters to bear an effective load. This improves stability by widening the base of support and reduces the load the tissue that supports the Ischial Tuberosities must bear.

High-Quality Foam Materials

Axiom SP Fluid is constructed with foam that has a high IFD and density. The dual density polyurethane foam base offers firm support in the lower layer with a durable comfort layer on top. High-quality materials lead to a long-lasting, comfortable, and high-performing product.

Surface Tension Reduction

The Hydrolite fluid bladder sits on top of the waterproof inner cover; reducing surface tension and maximizing envelopment of the ischia and coccyx. The bladder rests directly under the super stretch outer cover, allowing it to conform to the tissues supporting the Ischial Tuberosities. By using the super 4-way stretch Lycra outer cover material, surface tension is reduced, providing better immersion into the well.

Pre-Contoured Shape

It's important for all cushions to have a properly designed pre-contoured shape. That's why we cooperated with Georgia Tech to study anthropometrics. Axiom SP Fluid has a properly designed pre-contoured shape. Axiom SP Fluid is designed to provide increased immersion, allowing the trochanters to bear an effective load, widening the base of support, and reducing the load the Ischial Tuberosities must bear.

Feature Rich Covers

Axiom SP Fluid has an innovative cover that is aesthetically pleasing with functional benefits for both the client and caregiver. The super 4-way stretch Lycra outer cover reduces surface tension while the pleated 4-way stretch inner cover with self-sealing zipper is water resistant and is easy to clean. The water-resistant zipper and loop zipper pull make it simple to don and doff the cover while protecting the foam. There is an easy-to-reach front handle with utility loops for hanging accessories.

Specifications:

Width

14" - 22", 35.5 - 55.9 cm

Depth 14" - 22", 35.5 - 55.9 cm
Height (Leg Troughs) 3.3", 8.3 cm
Height (Overall) 4.5", 11.4 cm
Weight 3.6 lbs, 1.63 kg
Weight Capacity 350 lbs, 158 kg

Download Brochure

Download Manual

Cura360 Return Policy

Most products featured on Cura360.com can be returned within 30 days of purchase depending upon the manufacturer.
 
For specific return information, please contact Cura360's Customer Service Department at [email protected] or call 833-207-3433 for Authorization. Returns can not be processed without contacting Cura360 first, and some items are non-returnable when opened due to health risks.

Generally, you can expect a credit or refund, less a restocking and handling fee, in the same form of payment originally used for your purchase. Credits will be issued within 30 days of the manufacturer receiving your returned product back complete and in good and unused condition; and issuing Cura360 an Approval. You will be refunded the purchase price, less the Restocking Fee & applicable shipping costs. Customer is responsible for the Return Label. 
  • Restocking Fees range based on the Manufacturers policies, typically between 20-30%
  • All returns MUST be pre-approved
  • If a return is not received by the carrier within 15 days after the request has been approved we will consider the item as not returned and a refund will not be processed
  • Shipping costs are not reimbursable 
  • Returns due to Damage or Defect must be reported as soon as possible and pictures may be required
IMPORTANT If there is significant visible damage to the carton upon receipt, request that the driver note the damage and request a claim be filed with the carrier for damage. You should also immediately contact Cura360 Customer Service at  [email protected] or call 833-207-3433   

 

Ki Mobility warrants the frame, cross braces, hangers and quick-release axles of your Catalyst wheelchair against defects in materials and workmanship for the life of the original purchaser. All other parts and components of this wheelchair are warranted against defects in materials and workmanship for one year from the date of first consumer purchase. The expected life of the frame is five years.

Limitations to the Warranty

1. We do not warrant: a. Wear items: Upholstery, tires, armrest pads, tubes, armrests and push-handle grips. b. Damage resulting from neglect, misuse or from improper installation or repair. c. Damage from exceeding weight limit.

2. This warranty is VOID if the original chair serial number tag is removed or altered.

3. This warranty is VOID if the original chair has been modified from its original condition and it is determined the modification resulted in failure.

4. This warranty applies in the USA only. Check with your supplier to find out if international warranties apply. Ki Mobility’s Responsibility Ki Mobility’s only liability is to replace or repair, at our discretion, the covered parts. There are no other remedies, expressed or implied.

Your Responsibility a. Notify Ki Mobility, via an authorized supplier, prior to the end of the warranty period and get a return authorization (RA) for the return or repair of the covered parts. b. Have the supplier send the authorized return, freight pre-paid, to:

Ki Mobility 5201 Woodward Drive Stevens Point, WI 54481

c. Pay any charges for labor to repair or install parts.




The Accessories field is required

Safe Checkout:

  • PayPal
  • PayTomorrow
  • Discover
  • American Express
  • Master Card
  • Visa
  • Visa

Hydrolite Fluid Bladder

The Axiom SP Fluid uses a Hydrolite fluid bladder instead of Viscoelastic Foam. The bladder rests directly under the super stretch outer cover, allowing it to conform to the tissues supporting the Ischial Tuberosities.

Hydrolite is a non-Newtonian fluid that behaves as a solid under the force of gravity, but flows as a viscous fluid under load, which can help minimize shear. It is also incredibly light, eliminating the "weight penalty" of other fluid cushions. It is less temperature sensitive than other fluids, meaning it will provide more consistent performance regardless of climate.

Increased Immersion

Axiom SP Visco is designed to provide increased immersion, allowing the trochanters to bear an effective load. This improves stability by widening the base of support and reduces the load the tissue that supports the Ischial Tuberosities must bear. A thick section of specially designed Viscoelastic foam deforms to immerse and envelop the Ischial Tuberosities.

Increased Envelopment

Axiom SP Fluid is designed to provide increased envelopment, allowing the trochanters to bear an effective load. This improves stability by widening the base of support and reduces the load the tissue that supports the Ischial Tuberosities must bear.

High-Quality Foam Materials

Axiom SP Fluid is constructed with foam that has a high IFD and density. The dual density polyurethane foam base offers firm support in the lower layer with a durable comfort layer on top. High-quality materials lead to a long-lasting, comfortable, and high-performing product.

Surface Tension Reduction

The Hydrolite fluid bladder sits on top of the waterproof inner cover; reducing surface tension and maximizing envelopment of the ischia and coccyx. The bladder rests directly under the super stretch outer cover, allowing it to conform to the tissues supporting the Ischial Tuberosities. By using the super 4-way stretch Lycra outer cover material, surface tension is reduced, providing better immersion into the well.

Pre-Contoured Shape

It's important for all cushions to have a properly designed pre-contoured shape. That's why we cooperated with Georgia Tech to study anthropometrics. Axiom SP Fluid has a properly designed pre-contoured shape. Axiom SP Fluid is designed to provide increased immersion, allowing the trochanters to bear an effective load, widening the base of support, and reducing the load the Ischial Tuberosities must bear.

Feature Rich Covers

Axiom SP Fluid has an innovative cover that is aesthetically pleasing with functional benefits for both the client and caregiver. The super 4-way stretch Lycra outer cover reduces surface tension while the pleated 4-way stretch inner cover with self-sealing zipper is water resistant and is easy to clean. The water-resistant zipper and loop zipper pull make it simple to don and doff the cover while protecting the foam. There is an easy-to-reach front handle with utility loops for hanging accessories.

Specifications:

Width

14" - 22", 35.5 - 55.9 cm

Depth 14" - 22", 35.5 - 55.9 cm
Height (Leg Troughs) 3.3", 8.3 cm
Height (Overall) 4.5", 11.4 cm
Weight 3.6 lbs, 1.63 kg
Weight Capacity 350 lbs, 158 kg

Download Brochure

Download Manual

Cura360 Return Policy

Most products featured on Cura360.com can be returned within 30 days of purchase depending upon the manufacturer.
 
For specific return information, please contact Cura360's Customer Service Department at [email protected] or call 833-207-3433 for Authorization. Returns can not be processed without contacting Cura360 first, and some items are non-returnable when opened due to health risks.

Generally, you can expect a credit or refund, less a restocking and handling fee, in the same form of payment originally used for your purchase. Credits will be issued within 30 days of the manufacturer receiving your returned product back complete and in good and unused condition; and issuing Cura360 an Approval. You will be refunded the purchase price, less the Restocking Fee & applicable shipping costs. Customer is responsible for the Return Label. 
  • Restocking Fees range based on the Manufacturers policies, typically between 20-30%
  • All returns MUST be pre-approved
  • If a return is not received by the carrier within 15 days after the request has been approved we will consider the item as not returned and a refund will not be processed
  • Shipping costs are not reimbursable 
  • Returns due to Damage or Defect must be reported as soon as possible and pictures may be required
IMPORTANT If there is significant visible damage to the carton upon receipt, request that the driver note the damage and request a claim be filed with the carrier for damage. You should also immediately contact Cura360 Customer Service at  [email protected] or call 833-207-3433   

 

Ki Mobility warrants the frame, cross braces, hangers and quick-release axles of your Catalyst wheelchair against defects in materials and workmanship for the life of the original purchaser. All other parts and components of this wheelchair are warranted against defects in materials and workmanship for one year from the date of first consumer purchase. The expected life of the frame is five years.

Limitations to the Warranty

1. We do not warrant: a. Wear items: Upholstery, tires, armrest pads, tubes, armrests and push-handle grips. b. Damage resulting from neglect, misuse or from improper installation or repair. c. Damage from exceeding weight limit.

2. This warranty is VOID if the original chair serial number tag is removed or altered.

3. This warranty is VOID if the original chair has been modified from its original condition and it is determined the modification resulted in failure.

4. This warranty applies in the USA only. Check with your supplier to find out if international warranties apply. Ki Mobility’s Responsibility Ki Mobility’s only liability is to replace or repair, at our discretion, the covered parts. There are no other remedies, expressed or implied.

Your Responsibility a. Notify Ki Mobility, via an authorized supplier, prior to the end of the warranty period and get a return authorization (RA) for the return or repair of the covered parts. b. Have the supplier send the authorized return, freight pre-paid, to:

Ki Mobility 5201 Woodward Drive Stevens Point, WI 54481

c. Pay any charges for labor to repair or install parts.